Table of Content
His report was very user friendly and detailed, and the photos and videos were very valuable. We would recommend him highly and without reservation to any prospective home purchaser. We would never have known about these issues and would have made a huge mistake without Gary's professional help. The air admittance valve shall be installed not less than 6 inches above insulation materials where installed in attics. An AAV can significantly reduce the amount of venting materials needed in a plumbing system.

A Dynamic Favorites List is automatically created from your purchase history based on the timeframe, ship-to name, and product categories you want included. This list updates each time you open it based on the criteria selected. If you add an AAV leave access to maintain the vent. It’s mechanical – and all mechanical parts eventually wear out…and Yes, check with your local code office – some jurisdictions won’t allow an AAV. During maintenance you’ll want to be assured the top of the vent is kept open.
How to Install an Oatey Sure-Vent AAV
My first solution was to have septic tanks cleaned and checked, and a local tradesman completed this task and indicated the tanks were in good condition. I have now started to simply replace the AAV in the areas where the smell is identified. The source of smell seems to move within the areas as I replace the AAVs. I have now replaced 5 AAVs with one bathroom sink where the smell will simply not go away.
A minimum of four inches above the horizontal branch drain . Difficult situation and still provided us excellent service. We definitely recommend him if you’re looking for somebody to conduct a home inspection. Air Admittance Valves may be used on grease traps as long as they are not subject to positive pressure.
Where Can AAVs be Installed?
If you are currently using Internet Explorer we recommend you switch to Edge or another supported browser to enjoy the best experience Oatey.com has to offer. The Sure-Vents are not designed for exposure to Ultra Violet Rays. Oatey® offers a wide range of Sure-Vent® Air Admittance Valves to enable installation in virtually any application.
I would like to know the answer to Trent Spivey’s question — is there a new plumbing code that allows for all plumbing vents to terminate in the attic with aav devices installed. When a horizontal branch connects to a stack more than four branch intervals from the top of the stack. The relief vent must be located between the connection of the branch to the stack and the first fixture connecting to the branch. The relief vent may also serve as a vent for the fixture. Likewise, they equalize the air pressure in your pipe, which allows them to drain properly and prevent those sewer gases from getting into your living space.
How Do Air Admittance Valves Work?
Superior engineering along with stringent quality standards ensure unmatched performance. Complies to ASSE Standard 1050 and 1051 and IAPMO listed sizes. Oatey Sure-Vent® AAVs are available in four sizes ranging from 8 Stack/24 Branch DFU to 160 Stack/500 Branch DFU.

A maximum deviation for plum of 15 degrees is allowed. US manufacturers offer warranties that range from 1 year to “lifetime”. You’ll want to seek out the warranty info.
Why are Air Admittance Valves Necessary?
This spring-loaded vent uses negative pressure to open and positive pressure to close. Also replaces secondary stack venting. Stack-type air admittance valves shall be located not less than 6 inches above the flood level rim of the highest fixture being vented. The air admittance valve shall be located within the maximum developed length permitted for the vent. STUDOR AAVs location must allow for adequate air to enter the valve. When located in a wall space or attic space lacking ventilation openings, opening shall be provided.
With its compact design, the STUDOR Mini-Vent Air Admittance Valve with PVC Adapter offers a simple drain and waste venting solution. Great for venting a single fixture or a group of bathroom fixtures, the Mini-Vent air admittance valve is designed to fit 1-1/2 in. Pipes and excels in tight applications. This 1-way valve automatically opens and takes in fresh air when negative pressure occurs from a fixture discharging into the plumbing system. When the water flow stops, the Mini-Vent closes naturally due to gravity, preventing the circulation of any bad bathroom or drain odors. Designed for residential and commercial use, the STUDOR Mini-Vent Air Admittance Valve can be used in conjunction with other STUDOR AAVs to complement larger high-rise building drainage systems.
A Static Favorites List is created by adding items to your list from Search and/or Browse results, product detail pages, and previous orders and invoices. You can also upload your list using the Excel template provided on the "Favorites List Management" page. Get the professional answers you deserve. Our digital help center is here to help you navigate Home Depot Pro's one-source solutions and get the job done right.

Trent , Alison – When using AAV – we need at least one vent from the plumbing system to push through the roof. STUDOR AAVs installed in attic area must be located a minimum of six (6”) inches above the ceiling insulation. The vent shall connect to the drain vertically to maintain an unobstructed opening in the piping to the STUDOR AAVs. Some state and local building departments prohibit AAVs.
The very essence of a vent is to prevent siphon and vacuum forces in building up in the system, it is also to provide an exit for the gases produced in the system. The AAV’s only function is to avoid costly installation of complicated vent system for isolated/difficult fixtures. Unless you want sewer gases entering your home when your plumbing is under positive pressure, you’ll want a venting system. And AAVs are mechanical devices that can accomplish the task easily. Magic Vent prevents siphonage without the need for additional piping outdoors. It also performs the function of a DWV system vent stack, protecting the trap seal from siphonage without the need for additional piping to the outdoors.

Locating the valve in a sink or vanity cabinet is acceptable. In addition, before installing an air admittance valve to your plumbing system, check with your local building department to ensure using an AAV in your home is up to code. Here is the plumbing code for Ohio.
The active air valve is designed with an exclusive vermin protection system to keep out insects and foreign objects. The total amount of the cross-sectional area of vents combined on the system has to equal the aggregate cross-sectional area of the building drain. When properly installed an air admittance valve in the system is equivalent to an open vent pipe having the same cross sectional area as any other vent.

The temperature ranges that the Sure-Vent will operate in are -40°F to 150°F, your attic can experience drastic temperature variations depending on how it is vented and your geographic location. Insulation fibers can get caught inside the diaphragm which will make it harder for the diaphragm to open, or achieve a good seal when it is in the closed position. The Sure-Vent should be installed a minimum of six inches above the finished height of your insulation, and the attic must have an access point to conduct scheduled maintenance. Seven hours away and at a disadvantage in not being able to be on site and look closely ourselves. We really liked the house and were anxious to close, however Gary's eagle eye pointed out several significant issues that gave us pause. He was very professional in his reporting and tried to lay out the facts as he saw them in plain english.
No comments: